Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int. j. morphol ; 40(4): 920-926, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1405233

RESUMO

SUMMARY: To evaluate the skeletal, dento-alveolar and soft tissue morphology changes after maxillary molar distalization by clear aligner therapy and identify the significant efficacy of molar distalization,18 patients in conformity with the inclusion criteria were selected. Pre- and post-treatment Cone Beam Computed Tomography (CBCT) were examined to measure the angular and linear parameters. All subjects were completed non-extraction clear aligner treatment by distalizing molars. A paired-t test and independent-samples t-test were performed to observe the difference between before and after treatment and the difference between the first molar and second molar respectively. P-values <0.05 were considered statistically significant. Predicted movement rate was calculated by the formula: (actual movement(mm)/planned movement(mm)) x100%. Most variables of pre- and post-treatment showed no statistical difference(P<0.05), excepting SNA angle (P<0.05) and Upper lip/E-line linear (P<0.01) due to incisor retraction. The first and second molar revealed a translation movement without significant tipping and vertical movement. Clear aligners provided a high predictability (83.44 %) of distalization the maxillary first molar, and 85.14 % of the maxillary second molar. Clear aligners can effectively achieve distal displacement of molars.


RESUMEN: Se seleccionaron 18 pacientes, de acuerdo con los criterios de inclusión, para evaluar los cambios en la morfología esquelética, dentoalveolar y de los tejidos blandos después de la distalización de los molares maxilares, mediante la terapia con alineadores transparentes e así identificar la significativa eficacia de la distalización de los molares. Se examinó a través de tomografía computarizada de haz cónico (CBCT) antes y después del tratamiento para medir los parámetros angulares y lineales. Todos los sujetos completaron el tratamiento con alineadores transparentes sin extracción mediante la distalización de los molares. Se realizó una prueba t pareada y una prueba t de muestras independientes para observar la diferencia entre antes y después del tratamiento y la diferencia entre el primer molar y el segundo molar, respectivamente. Los valores de p<0,05 se consideraron estadísticamente significativos. La tasa de movimiento prevista se calculó mediante la fórmula: (movimiento real (mm)/movimiento planificado (mm)) x 100 %. La mayoría de las variables de pre y postratamiento no mostraron diferencia estadística (P<0,05), excepto el ángulo SNA (P<0,05) y el labio superior/línea E lineal (P<0,01) debido a la retracción del incisivo. El primer y segundo molar revelaron un movimiento de traslación sin inclinación significativa y movimiento vertical. Los alineadores transparentes proporcionaron una alta previsibilidad (83,44 %) de la distalización del primer molar superior y del 85,14 % del segundo molar superior. Los alineadores transparentes pueden lograr efectivamente el desplazamiento distal de los molares.


Assuntos
Humanos , Técnicas de Movimentação Dentária/métodos , Cefalometria , Má Oclusão/terapia , Dente Molar , Aparelhos Ortodônticos Removíveis , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico
2.
Int. j. morphol ; 38(4): 1053-1059, Aug. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1124896

RESUMO

The aim of this study was to evaluate the hard and soft tissue profile changes following treatment of functional and mild skeletal class III malocclusion in mixed dentition by means of the Frankel functional regulator (FR-3) appliance, and to reveal the mechanism and effectiveness of treatment with FR-3 appliance. Twenty-six patients (chronological mean age, 8.7±1.4 years; mean treatment duration, 10.3±1.3 months) with functional and mild skeletal class III malocclusion were selected and treated with FR-3 appliances. Lateral cephalogram was taken pre- and post-treatment, and the data was analyzed by paired-samples t test with SPSS22.0 software package. Differences were considered statistically significant at P < 0.05. The results demonstrated that the FR-3 appliance produced a statistically significant decrease in L1-NB, L1-MP, U1-L1 (P<0.01) and an increase greatly in ANB, MP-FH, Y axis, ANSMe, ANS-Me/N-Me and overjet (P<0.01). SNA, SNB were increased significantly (P<0.05). Meanwhile, N'-Sn-Pog', ULSn-SN, LLSiSN increased, S-N'-Si, LL-EP decreased with significant difference (P<0.01). S-N'-Sn, Cm-Sn-UL, UL-EP, Sn-Mes and Ns-Mes increased with significant difference (P<0.05). Therefore it was concluded that after FR-3 treatment, the position of mandible may rotate clockwise backwards and downwards, with the labioversion of upper incisors and linguoversion of lower incisors. Although point A moved mesially, the length and position of the maxilla did not change significantly. With the protrusion of upper lip and the retrusion of lower lip, the relationship among nose, upper lip, lower lip and chin become harmonious, the profile of soft tissue is more coordinated and attractive.


El objetivo de este estudio fue evaluar los cambios en el perfil de los tejidos duros y blandos después del tratamiento de la maloclusión funcional y leve de la clase III esquelética en la dentición mixta mediante el aparato regulador funcional Frankel (FR-3), y revelar el mecanismo y efectividad del tratamiento con el aparato FR-3. Veintiseis pacientes (edad media 8,7 ± 1,4 años; duración media del tratamiento, 10,3 ± 1,3 meses) con maloclusión funcional y leve de clase esquelética III fueron seleccionados y tratados con aparatos FR-3. El cefalograma lateral se tomó antes y después del tratamiento, y los datos se analizaron mediante la prueba t de muestras con el software SPSS22.0. Las diferencias se consideraron estadísticamente significativas a P <0,05. Los resultados demostraron que el dispositivo FR-3 produjo una disminución estadísticamente significativa en L1-NB, L1MP, U1-L1 (P <0,01) y un gran aumento en ANB, MP-FH, eje Y, ANS-Me, ANS -Me / N-Me y overjet (P <0,01). SNA, SNB se incrementaron significativamente (P <0,05). Mientras tanto, N'Sn-Pog', ULSn-SN, LLSi-SN aumentaron, S-N'-Si, LL-EP disminuyeron con una diferencia significativa (P <0,01). S-N'-Sn, Cm-Sn-UL, UL-EP, Sn-Mes y Ns-Mes aumentaron con una diferencia significativa (P <0,05). Por lo tanto, se concluyó que después del tratamiento con FR-3, la posición de la mandíbula puede girar en sentido reloj hacia atrás y hacia abajo, con labioversión de los incisivos superiores y linguoversión de los incisivos inferiores. Aunque el punto A se movió mesialmente, la longitud y la posición del maxilar no cambiaron significativamente. Con la protuberancia del labio superior y la retrusión del labio inferior, la relación entre la nariz, el labio superior, el labio inferior y el mentón se armoniza, el perfil del tejido blando es más coordinado y atractivo.


Assuntos
Humanos , Masculino , Feminino , Criança , Aparelhos Ortodônticos Funcionais , Dentição Mista , Má Oclusão Classe III de Angle/patologia , Má Oclusão Classe III de Angle/terapia , Cefalometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...